site stats

Interspace knee spacer

WebInterSpace Knee is designed to temporarily replace an infected implant during a Total Knee Arthroplasty (TKA) and provide the patient with mobility and predictable, consistent local … WebSpacer® K - InterSpace Knee (USA) Spacer K resembles a knee prosthesis made in bone cement with gentamicin. It comprises two independent articulating elements. The tibial …

AccessGUDID - DEVICE: InterSpace Knee (28031497000583)

WebAccessGUDID - InterSpace Knee (28031497000606)- Temporary knee spacer with gentamicin. InterSpace Knee is composed of fully formed … WebSpacer for Knee Spacer® K - InterSpace Knee (USA) Spacer K resembles a knee prosthesis made in bone cement with gentamicin. It comprises two independent articulating elements. The tibial component has a flat base on which the femoral component articulates. Available in 3 sizes. The proximal cementation of the neck with bone cement is compulsory. collierville schools pay scale https://avanteseguros.com

Temporaty knee spacer - All medical device manufacturers

WebAbout InterSpace Knee (Prod 3695) Preformed, temporary, articulated knee spacer impregnated with Gentamicin for two-stage revision arthroplasty. Partial load bearing. … WebDec 1, 2024 · ALBC High Functional Knee Articulating Spacer Preparation - Implants & Materials Required: (A) Bone Cement x 40 g pack (usually 3 to 4 batches are needed): 3 g of Vancomycin, 3.6 g of Tobramycin and 150 of Amphotericin powder (if concerns for fungal infection) / batch. Methylene blue 1ml per batch and Mineral Oil. dr riley statesboro ga

Spacer - Tecres - Catalogue PDF Documentation technique

Category:AccessGUDID - DEVICE: InterSpace Knee (28031497000590)

Tags:Interspace knee spacer

Interspace knee spacer

AccessGUDID - DEVICE: InterSpace Knee (28031497000583)

WebAccessGUDID - InterSpace Knee (28031497000583)- Temporary knee spacer with gentamicin. InterSpace Knee is composed of fully formed … WebInterSpace Knee, Hip and Shoulder are preformed, articulating, partial load-bearing structures comprised of gentamicin-impregnated PMMA bone cement. InterSpace is …

Interspace knee spacer

Did you know?

Webthe interSpace Knee resembles an ultra-congruent condylar knee prosthesis. it consists of two articulating independent elements. the tibial component has a flat base upon which … WebJan 24, 2024 · A potential disadvantage of the prefabricated spacers that may affect their clinical efficacy is the limited type and amount of antibiotics used . The dosage of gentamicin in the InterSpace knee spacer ranges from 0.8 to 1.7 g, which is below the recommended dose of 3.6 g per 40.0 g cement .

WebNov 14, 2024 · Dynamic spacers are recommended whenever possible in two-stage revision for infected total knee arthroplasty. Although the evidence level is low, some benefits were reported favoring dynamic spacers, such as better ROM, shorter hospital stay, and better eventual outcome following the second stage revision. WebAug 1, 2024 · Simultaneous prosthetic joint infection of ipsilateral hip and knee arthroplasties is often accompanied by significant bone loss and presents a challenging reconstructive problem. Two-stage reconstruction is favored and requires the placement of a total femur spacer, which is not a commercially available device. We describe a surgical …

WebOct 8, 2015 · AccessGUDID - InterSpace Knee (28031497001160)- Temporary knee spacer with gentamicin. InterSpace Knee is composed of fully formed … WebInterSpace Knee and Shoulder Spacers ... Knee; InterSpace® Shoulder), serving as the precedent for all commercial products that follow. 5. Design Philosophy InterSpace was designed to provide patients with a higher quality of life and surgeons with a greater sense of control during their

Webpoly(methyl methacrylate) spacers (InterSpace Knee, Exactech Inc., Gainesville, FL; or The Remedy, OsteoRemedies, Memphis, TN), which contain 1.2 g of gentamicin in each of the femoral and

WebAccessGUDID - InterSpace Knee (28031497000583)- Temporary knee spacer with gentamicin. InterSpace Knee is composed of fully formed gentamicin/polymethylmethacrylate (PMMA) radiopaque bone cement. The device is sterile and single-use. InterSpace Knee is indicated for temporary use (maximum of 180 days) … collierville swim team unifyWebOct 8, 2015 · AccessGUDID - InterSpace Knee (28031497000590)- Temporary knee spacer with gentamicin. InterSpace Knee is composed of fully formed gentamicin/polymethylmethacrylate (PMMA) radiopaque bone cement. The device is sterile and single-use. InterSpace Knee is indicated for temporary use (maximum of 180 days) … collierville roof repair homeWebH-ip Modular Spacer Knee Modular Spacer 2.2 Common/Usual Name Modular temporary hip prosthesis with gentamicin Modular temporary knee prosthesis with gentamicin Bone ... The predicate devices are the Tecres Interspace Hip and Knee devices cleared in 5 10(k) submissions K101 356. The ... dr riley spiesWebThe most widely studied spacer technology in the world, InterSpace® is the first pre-formed spacer with 93.3 percent eradication rate.1 Its positive clinical results coupled with the systematic research of surgeon-made devices led to the design of products that could be both mechanically safe and pharmacologically effective. InterSpace Knee ... collierville schools teacher pay scaleWebDec 1, 2024 · Wan et al [12] evaluated the InterSpace knee spacer (Exactech, Gainesville, FL) and demonstrated infection eradication in 30 of 33 cases at 2 years. Westrich et al [ 22 ] also reported on the Exactech spacer in 3 cases of a 75 knee series with no significant difference in infection eradication between this and other types of articulating spacers in … collierville schools covid testingWebExactech SpacersInterSpace®: Trust the Science.More than 20 years as your proven infection remedy.The most widely studied spacer technology in the world, Int... collierville sports and recWebInterSpace® Knee SPK0022 Small SPK0122 Medium SPK0222 Large SPK0322 XL SPK90Z2 Trials (S,M,L) SPK03Z1 Trial (XL) InterSpace® Hip Trials SPC90Z1 Short … collierville schools substitute teacher